Our solvent dispenser base model
The DS2 is our traditional base model of solvent dispensers. It comes with various options, allowing customers to buy devices that respond to their specific needs.
Customers can choose a dispenser with one, two, or four bushings. The bushings are designed to dispense solvent at a predetermined depth, either internally (ID) or externally (OD).
Below are the primary options available to customers:
Sliding Door (SD)
The sliding door closes when the dispenser switches off or when the audio-visual alarm is triggered.
Vapor Conveyor System (VCS)
The VCS includes an exhaust tube adapter that removes solvent vapors from the working area to achieve minimal environmental contamination.
Level Sensor (LS)
The LS is an audio-visual signaling system that alerts the operator when the reservoir level is low.
Electronic Flow Regulator (EFR)
The EFR allows supervisors to program the level sensor that signals low solvent level and adjust the pumping frequency that determines the solvent flow.
Here is a list of other traditional dispenser solvents (check brochure and media gallery for additional information):
Power Supply | 115-230V, 50-60Hz 10 VA |
Working Voltage | 24V, 50Hz |
Operating Temperature | 5° – 45° C |
Storage Temperature | 68°F/20°C – 86°F/30°C |
Dispensing Bushing (type, min-max) | OD: 3.0/8.0mm – 8.1/12.5mm, ID: 2.5/12.0mm |
Relative Room Humidity | 90% max |
Vapour conveyor system aspiration flow | With VCS 5/10 cubic meters/hour |
VCS Air Speed | With 0.3/0.5 cubic meters/hour |
Various languages sliding door inscription | English, Spanish, Italian, and more at customer’s request |
Solvent Tank Capacity | 70 ml |
Solvent Level Sensor | Optional |
Alerting System | Optional |
Vapor Conveyor System (VCS) | Optional |